Testing underway in Toulouse for SPIRou’s cryostat

Testing underway in Toulouse for SPIRou’s cryostat
SPIRou’s cryostat. (Credit: LAE/OMM)

The second phase of cryo-mechanical integration of the SPIRou spectrograph is underway at IRAP/OMP (Toulouse, France), with cryostat cooling tests as part of the acceptance procedure.

Following assembly and alignment of the cryo-mechanics, the primary vacuum pump, turbo-molecular pump, cryogenic compressors and all gauges and sensors have been connected.

The first step was to establish the vacuum inside the cryostat down to 10-2 mbar. The turbo-molecular pump then resumed to reach a higher vacuum of 10-5 mbar. This stage, during which all the materials inside the cryostat exit naturally (rejecting dust and particles, in particular the multilayer insulation), takes a few days to reach a stable state.

Cooling can then begin, using compressors and helium coolers to lower the temperature inside the cryostat from room temperature (300 K) down to 80 K. A key parameter for the velocimetric accuracy of SPIRou is temperature stability to within 2 mK. This performance, already achieved during the integration phase in Victoria at the NRC-H laboratories, will be validated during this first cooling cycle.

These activities are led by Leslie Saddlemyer and Rob Messing, both from NRC-H (Victoria, Canada) and Nicolas Striebig from IRAP / OMP.

Similar articles

SPIOMM, the OMM’s spy, unravels the mysteries of the Crab Nebula
6 December 2010

SPIOMM, the OMM’s spy, unravels the mysteries of the Crab Nebula

A team of researchers from CRAQ member Université Laval has produced the first three-dimensional map…

OMM delivers FGS/NIRISS to NASA
25 July 2012

OMM delivers FGS/NIRISS to NASA

Two instruments, whose acronyms are NIRISS and FGS, designed by a team co-led by Université…

SPIRou: a new Infrared SpectroPolarimeter
4 November 2013

SPIRou: a new Infrared SpectroPolarimeter

SPIRou is a new Infrared SpectroPolarimeter for discovering new habitable worlds and studying the birth…